Festoon cable
Festoon cable
Festoon cable
FOB
Application:
RNEDAFESTOON 0.6/1kV is flexible power and control flat cable for use on outdoor festoon system or frequent bending applications which requests high mechanical stresses and excellent bending performance.
Standard:
DIN VDE 250 – Part 814
Designation:
RNEDAFESTOON (N)GRDGOEU RNEDAFESTOON(C) (N)GRDGCGOEU RNEDA-TPU D12Y11Y RNEDA-TPU(C) D12Y11Y
Sample:Chargeable supportGet samples
Product details
Essential details
Shipping:Express Delivery
Product Introduction

Products Family

Cable Series
Description
Your Application
Equivalent Models
RNEDAFESTOON
EPR rubber insulated CR sheathed low voltage cables for festoon use. With tinned Copper and AL/PE Screened, data transmitting can be available

Festoon system of speed up to 180m/min,

especially for eRTG/RTG, RMG or Overhead cranes.

RONDOFLEX

2PNCT

RNEDAFESTOON(C)
EPR rubber insulated CR sheathed low voltage cables for festoon use with tinned Copper and AL/PE Screened

Festoon system of speed up to 180m/min,

especially for eRTG/RTG, RMG or Overhead cranes.

RONDOFLEX(C)
2PNCT-B

2PNCT-SB

2PNCT-PSB

RNEDA-TPU
TPE-E rubber insulated TPU sheathed low voltage cables for festoon use

Festoon system of speed up to 240m/min,

especially for QC.

FESTOONFLEX PUR HF

RNEDA-TPU
TPE-E rubber insulated TPU sheathed low voltage cables for festoon use with tinned Copper and AL/PE Screened

Festoon system of speed up to 240m/min,

especially for QC.

FESTOONFLEX C PUR HF

note:

Equivalent Models” means that our cable models are engineered according to the same standards, performance and parameters

such as outer diamenter and approximate weight levels as leading international products.


Main Parameters

Electrical parameters
Rated voltage
0.6/1 kV
Max. permissible operating voltage AC
0.7/1.2 kV
Max. permissible operating voltage DC
0.9/1.8 kV
AC Test Voltage (5min.)
3.5 kV
Mechanical parameters
Min. bending radius
10xO.D.
Max. travelling speed
Mono-spiral reel
240 m/min
Cylindrical drum
160 m/min
Thermal parameters
Ambient temperature for fixed installation
-50℃ > 80℃
Ambient temperature in fully flexible operation
-40℃  > 80℃
Max. permissible temperature at conductor
90℃
Max. short circuit temperature of the conductor
250℃
Chemical characteristics

Resistance to oil
DIN EN 60811-404; DIN VDE 0473-811-404
Weather resistance
Outdoor use, resistant to ozone, UV, moisture
Resistance to fire
IEC 60332-1


Support & Services

About Us
News
Investors

Contact Us

Products

Ports & Maritime

Fixed Installation

Industry & Tunneling

Oil & Gas

Contact Us

e-mail: welcome@hebei-huatong.com

tel.: +86 21 6558 8552

address: No.111 Huatong Avenue Fengnan District, Tangshan 063300 Hebei Province

P.R.China

address: No.111 Huatong Avenue Fengnan District, Tangshan 063300 Hebei Province

P.R.China